RECOVERY OF WATER FROM BOILER FLUE GAS - OSTI GOV

RECOVERY OF WATER FROM BOILER FLUE GAS - OSTI GOV Related Information

Recovery of Water from Boiler Flue Gas Using …

31/3/2011 · Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling. DOE has also been placing emphasis on recovery of usable water from sources not generally considered, such as mine water, water produced from oil and gas extraction, and water contained in boiler flue gas. This

boiler condensed water recovery rate

Guide to Managing the Condensate for Condensing Water Heaters. Sep 30, 2008 · @article{osti_952467, title = {Recovery of Water from Boiler Flue Gas}, author = {Levy, Edward and Bilirgen, Harun and Jeong, Kwangkook and Kessen, Michael and son, Christopher

Recovery of Water from Boiler Flue Gas (Technical …

30/9/2008 · Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers. Technical Report Levy, Edward ; Bilirgen, Harun ; DuPoint, John. Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling.

(PDF) Recovery of water from boiler flue gas | harun …

The FG-AHX1 heat exchanger system would allow for more water vapor to condense from the flue gas and the corresponding increase in boiler air inlet temperature would increase the efficiency of the boiler and decrease unit heat rate. A simplified diagram of the combined flue gas …

Recovery of Water from Boiler Flue Gas (Technical …

30/9/2008 · The U.S. Department of Energy's Office of Scientific and Technical Information OSTI.GOV Technical Report: Recovery of Water from Boiler Flue Gas

(PDF) Recovery of water from boiler flue gas | harun …

Recovery of water from boiler flue gas 2008 harun bilirgen Christopher Whitcombe Christopher son Kwangkook Jeong Michael Kessen Edward Levy harun bilirgen Christopher Whitcombe

Experimental investigation on vapor-pump equipped gas …

25/1/2019 · Since the water vapor produced by gas combustion is unchanged, the dew point temperature of the boiler output flue gas also increases. Thus in the gas-water heat exchanger, large amount of latent heat can be recovered by the network return water (45–50) °C.

Water recovery from flue gas condensate in municipal …

1/11/2020 · In cogeneration plants with wet scrubbing of exhaust gases, the resulting flue gas condensate passes through various treatment steps prior to its discharge to recipient water body or for use as boiler feed water. The present investigation examines membrane

[PDF] Recovery of Water from Boiler Flue Gas | Semantic …

Chemistry. This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor condensation rate.

Development of integrated technology for waste heat …

15/7/2021 · Taking a 140 MW coal-fired boiler as an example, in the range of 25%~ load rate, the direct energy saving can reach 118 to 523 kW∙h, the waste heat recovery power is 2.7 to 11.4 MW, and the coal saving can reach 374 to 1605 kg/h, resulting in energy 2

Recovery of Water from Boiler Flue Gas Using …

31/3/2011 · Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling. DOE has also been placing emphasis on recovery of usable water from sources not generally considered, such as mine water, water produced from oil and gas extraction, and water contained in boiler flue gas. This

RECOVERY OF WATER FROM BOILER FLUE GAS

RECOVERY OF WATER FROM BOILER FLUE GAS FINAL TECHNICAL REPORT January 1, 2006 to September 30, 2008 by Edward Levy Harun Bilirgen Kwangkook Jeong Michael Kessen Christopher son Christopher Whitcombe Report Issued

Recovery of water from boiler flue gas -

Recovery of water from boiler flue gas. This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor

RECOVERY OF WATER FROM BOILER FLUE GAS USING …

RECOVERY OF WATER FROM BOILER FLUE GAS USING CONDENSING HEAT EXCHANGERS FINAL TECHNICAL REPORT October 1, 2008 to March 31, 2011 by Edward Levy, Harun Bilirgen and John DuPont Report Issued June 2011 DOE Award Number

Flue Gas Water Vapor Latent Heat Recovery for …

ADVANTAGES Latent heat recovery can boost power generation efficiency of pressurized oxy-coal boiler by up to 14% TMC can recover clean water from flue gas equal to 2.0% of steam demand No boiler modifications required Reduced dew point of flue

Flue Gas Water Vapor Latent Heat Recovery for Pressurized Oxy-Combustion …

Latent heat recovery can boost power generation efficiency of pressurized oxy-coal boiler by up to 14% TMC can recover clean water from flue gas equal to 2.0% of steam demand No boiler modifications required Reduced dew point of flue gas 2, and NO

Figure 4-15 from Recovery of Water from Boiler Flue Gas | …

Chemistry. This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor condensation rate.

Flue Gas Water Vapor Latent Heat Recovery for Pressurized Oxy …

NETL CO 2 Capture Technology Meeting – August 2016 7 Technology Background ADVANTAGES Latent heat recovery can boost power generation efficiency of oxy-coal boiler by 14% TMC can recover clean water from flue gas equal to 2.0% of steam

heat recovery from flue gas

Get acid dew point of flue gas (Journal Article) | OSTI.GOV In boiler operation, heat loss to flue gases amounts to as much as 20 to 25% of the heat input. To recover heat from flue gases, economizers are generally used to preheat boiler make-up water or forced

Mass transfer performance of water recovery from flue …

1/12/2017 · Membrane technology is a potential way for water recovery from the flue gas of the lignite boiler. Consider the influences of the micro-scale configuration of the membrane and the operating parameters, the physical process was modeled based on the Stefan Maxwell theory, as well as the composite membrane resistance model for numerical simulation.

Want to buy a boiler for your project?